Switch language
  • Polski
Medical lasers
MedArt VariMedTM 810 nm

Silent, safe and efficient 810 nm Diode Laser System mainly used to permanent hair removal and treatments of vascular lesions.

Check possible presentation dates Use contact form
Laser Description

The MedArt VariMed system leads the way in performing safe and efficient hair removal on all skin types. In combination with the industry-leading MedArt scanner, VariMed offers fast and effective treatments on all body areas.

Video
Treatments
Vascular Lesions Treatment Area:
  • Telangiectasia
  • Spider Veins
  • Hemangiomas
  • Reticular Veins
  • Port Wine Stains
  • Rosacea Redness and Flushing 
  • Venous Lakes
  • Fine Varicose Vein
  • Transcutaneous Leg Vein
Endovascular Treatment of Larger Veins Treatment Area:
  • Vena Saphena Magna
  • Vena Saphena Parva
Hair Removal Treatment Area:

All Skin Types

Key advantages
  • Safe – Super long pulse with contact cooling window 
  • Versatile – A system for both hair removal & vascular lesion treatment  
  • Fast – Treatment of a man’s full back in 30 minutes 
  • Stable – Impressive long-term results
  • Silent – The quietest laser you will ever use
  • Low running cost – No consumables are required   
  • Built-In Power Meter
  • Quick Safe Connector – For endovascular treatment
Check possible presentation dates

Hair Removal

Setting New Standards for Permanent Hair Reduction

The MedArt VariMed system leads the way in performing safe and efficient hair removal on all skin types. In combination with the industry-leading MedArt scanner, VariMed offers fast and effective treatments on all body areas.

Industry Leading Scanner

The scanner places a series of 9 spots of 8 mm diameter, within the large 5.7 cm2 treatment area. The accurate spot overlap ensures an even energy distribution. Controls on the scanner itself enable the scan pattern to be changed conveniently to a single line or a single 8 mm spot for treating smaller areas, as well as enabling power adjustment options.

Safe Treatment

Treatment safety is enhanced by a combination of super long-pulse technology and contact cooling. The super longpulse enables safe treatment of darker skin types, and the pre, parallel and post treatment contact cooling down to 0°C increases patient comfort and minimizes the risk of unwanted side effects. An integrated power meter enables practitioners to verify power output at any time.

Compact, Easy to Use and Cost Efficient

The VariMed system is compact and portable. The intuitive user-friendly interface is easy to navigate, and running costs are minimized as it requires no consumables. The MedArt scanner is easy to operate with ergonomic design and a weight of just 290 g. The attached sapphire window provides pre, parallel and post treatment cooling.

Vascular Lesions

Transcutaneous Treatment of Vascular Lesions

Operating at 810 nm enables high absorption in oxyhaemoglobin combined with sufficient penetration depth to target larger, deeper vessels. Vessels of up to 4 mm in diameter are successfully treated. Often only a single treatment is required to close veins or clear lesions. During treatment the smallest veins immediately contract and disappear, whereas larger vessels coagulate and are absorbed in due course.

Integrated Contact Cooling System

The focused handpiece with a sapphire glass cooling window enables a more comfortable treatment of large vessels. The cooling system gives superior contact cooling, providing excellent skin protection during treatment especially for darker skin types, thus reducing the risk of side effects.

A Multi Purpose Vascular Solution

VariMed can now be upgraded for endovascular treatment of vena saphena magna and vena saphena parva using a bare fiber, making VariMed the complete vascular treatment system.

Specifications MedArt VariMedTM 810 nm
Laser Type Continuous Wave Diode Laser. Laser Class 4 (IEC 60825)
Max Fluence 200 J/cm2
Output Power Range 1 – 90 W
Wavelength 810 nm
Aiming Beam Red Indicator light through fiber (635 nm)
Mode of operation Continuous or Pulsed Operation
Frequency range 0.3 - 100 Hz
Pulse width 10 – 1000 ms
Spot size 1.2 mm, 2.5 mm, 4 mm with Cooling Hand Pieces
Fiber connection MedArt Quick Safe Connect
Fiber diameter 1000 μm or larger
Fiber length 165 cm
Frequency range Min 0.3 Hz / Max 100 Hz
Handpiece Straight Handpiece or Scanner
Output Power Meter 1 W – 150 W
Main voltage 100-240 V, 50/60 Hz
Safety class I type BF
Size 58 x 46 x 16 cm
Weight 18 kg
Product code MedArt 435
Certifications CE 0459 / FDA
Endovenous
Endovenous Fiber Diameter 600 μm
Scanner specification
Spot size 8 mm
Scan pattern Square / Line / Single Spot
Treatment area 24x24 mm, 24 x 8 mm, 8 mm
Scanning time 0.5 – 4 s
Indication of settings 9 Green LED Indicators
Treatment distance 58 mm
Optical power efficiency Typically > 98%
Dimensions 12 x 11 x 2.5 cm
Weight 290 g
Safety class I type BF
Product code MedArt 413
Certifications CE 0459 / FDA
Cooling Specifications
Cooling temperature range 0 – 20oC (32 – 68oF)
Operating conditions Ambient temperature <28oC / 83oF
Cooling liquid Volume 250 ml, 70% Purified Water / 30% Pure Alcohol
Main voltage 100-240 V, 50/60 Hz
Size 51.5 x 30 x 15 cm
Weight 11 kg
Product code MedArt 525
Certifications CE 0459 / FDA